Nortel Business Communications Manager 400 Technical Specifications
Business Communications Manager 400 Technical Specifications
Nortel BCM 400 Technical Specifications
BCM 400 Technical Specifications
BCM 200 Technical Specifications
Nortel BCM50 Technical Specifications
Nortel BCM Base unit
Physical dimensions of the Nortel BCM 400 and Physical dimensions of the Nortel BCM 200
Depth 18.3 in.; 46.5 cm 18.3 in.; 46.5 cm
Width 17.5 in.; 44.5 cm 17.5 in.; 44.5 cm
Height 7.1 in.; 18.0 cm 3.5 in.; 9.0 cm
Weight Std. 35.2 lbs; Std. 24.9 lbs;
15.9 Kg 11.3 Kg
Redundant 46.7 lbs;
21.2 Kg
Components of the Nortel BCM 400 BCM 200
Media Bay Module Bays Four Two
CPU Processor Intel Celeron 1.2 GHz Intel Celeron 1.2 GHz
Memory (RAM) 256 MB SDRAM 256 MB SDRAM
Hard Drive 20 GB EIDE 20 GB EIDE
System Status LEDs
Power status, Hard drive activity, System status, PCI device monitoring
(MSC, WAN, NIC 1, NIC 2), Chassis/CPU temperature, Fan activity
reset button
The System Status Monitor Card controls and monitors fans, power
supply, chassis temperature and OS status.
Mounting options
Rack-mount (standard 19-inch rack); Stand-alone (feet included); Wallmount
(optional wall-mount bracket available separately)
Power supply specifications
Standard power supply Redundant power supply (BCM400 only)
Auto-sensing Auto-sensing
300 Watts 350 Watts
90/264 VAC 90/264 VAC
6.0 A/3.0 A 7.0 A/3.5 A
60/50 Hz 60/50 Hz
Environmental specifications of the Nortel BCM 400
Environmental specifications of the Nortel BCM 200
Operating temperature 32º to 104ºF; 0º to 40ºC
Operating humidity 10% to 90% relative humidity,
non-condensing
Storage temperature -67º to 158ºF; -55º to 70ºC
Storage humidity Up to 95% relative humidity
Mechanical requirements
NEBS (GR-63-CORE) compliant for Transportation and Operational
Vibration per IEC 68-2-27, Package Drop Shock resistance per ISTA 1A
Transportation Bounce to IEC 68-2-55 and Unpackaged Drop to ISTA
Project 1A
Regulatory compliance
Electromagnetic emissions
Radiated Air Australia AS3548 Class A
North America CISPR22 Class A
United Kingdom EN55022 Class A
Conducted Power Leads Australia AS3548 Class A
North America CISPR22 Class A
United Kingdom EN55022 Class A
Immunity (Narrow band RF interference)
Radiated North America customer driven
(based on EN 61000-4-3)
United Kingdom/International
EN55024 : 1998
Conducted North America customer driven
(Based on EN 61000-4-6)
United Kingdom/International
EN55024 : 1998
Immunity to electrostatic discharge
Indirect No functional impairment up to +/- 8 kV
Direct Mated I/O ports and connectors,
No damage up to +/- 4 kV
Mated connector and cords,
No functional impairment up to +/- 8 kV,
No damage up to +/- 15 kV
Network protection of the Nortel BCM 400
Network protection of the Nortel BCM200
•Australia TS038/31/03/04/01
• EU CTR12/13/3/4/21
• North America/CALA FCC Part 68, CS 03 Issue 8
Safety and surge/transient
•Australia TS038/31/02/03/04, ACA TS001, AS/NZS 3260
•NA/CALA/APAC IEC/EN 60950-1 (including all group and national deviations)
and CSA C22.2 No. 60950-1, UL60950-1
• EU CTR12/13/3/4/21, EN 60950 (with national deviations)
Telephony components of the Nortel BCM 400 and Telephony components of the Nortel BCM 200
Media Services Card (BCM-MSC)
• One 8-pin modular jack (RJ-45) connection for Expansion Chassis
(Only on BCM400 not BCM200)
• Four 3.5 mm (1/8 inch) standard miniature stereo (3-conductor)
Safety Extra Low
•Voltage (SELV) jacks for auxiliary ringer, page relay, page output and
music on hold
•Auxiliary ringer switch capacity of 50mA (non-inductive) at 40 V
(maximum)
•Page Relay switch capacity of 50mA (non-inductive) at 40 V
(maximum)
•Page Output 600 ohms impedance
• Music on hold mono input
• Media Services Processor Expansion Card slots
— BCM400—four slots, two equipped
— BCM200—two slots, one equipped
•Supports maximum of 8 DS-30s. Allows 2/6 and 3/5 IP/TDM Splits.
Media Bay Modules of the Nortel BCM 400 and Media Bay Modules of the Nortel BCM 200
16 Stn Digital Station Media Bay Module+ (DSM 16+)
• One Amphenol (male) connector (25 pair)
• Individual interfaces are current connector (25-pair); limited to 80 mA
• 16 digital phone ports
• Two LEDs: Power, Status
• Utilizes 1/2 DS-30 (with DIP switch set appropriately)
32 Stn Digital Station Media Bay Module+ (DSM 32+)
• Two Amphenol (male)
• Individual interfaces are current connectors (25 pair); limited to 80 mA
• 32 digital phone ports
• Two LEDs: Power, Status
• Utilizes 1 DS-30 (with DIP switch set appropriately)
8 Stn Analog Station Media Bay Module (GASM 8)
• One Amphenol (male) connector (25 pair)
• Maximum modem connection speed: 28.8 kbps
• 8 analog phone ports
• Loop length 26G 2600 ft, 24G 4000 ft; 22G 6500 ft
• Disconnect Supervision-850 ms. Momentary Disconnect (Open Switch
Interval (OSI) as per TIA/EIA 464)
•Message Waiting Indication — NA 120V. 600 ms On and 1000 ms Off.
UK reverse polarity
• Analog connectivity support for Poland and Australia
•Calling Line Identification (CLID) Name and Number — NA per Bell 202
standard. UK per SIN 227/224.
•Two LEDs: Power, Status
• Utilizes 1/4 DS-30 (with DIP switch set appropriately)
Digital Trunk Media Bay Module (DTM)
• One 8-pin RJ-45C modular jack
• T1 trunk interface with integrated CSU
•24 B channels with T1 interface (supports DSX-1 and DS1 interfaces)
•23 B channels with North American PRI interface
• LEDs: Power, Status, In-service, Loop-back, Test, Receive Alarm,
Receive Error, Transmit Alarm, Transmit Error
• 30 digital channels with ETSI PRI Interface
• Utilizes 1 (one) DS-30
Digital Drop and Insert MUX Media Bay Module (DDIM)
• One 8-pin RJ-45C modular jack
• T1 trunk interface with integrated CSU
•24 B channels with T1 interface (supports DSX-1 and DS1 interfaces)
• LEDs: Power, Status, In-service, Loop-back Test, Receive Alarm,
Receive Error, Transmit Alarm, Transmit Error
• LEDs: Transmit, Receive, RTS, CTS, DCD, DSR, TM
•V.35-DB26 miniature connector
•Cables: V.35, BCM WAN, Nortel Routers, DB-60 cable
• Utilizes two DS-30s
Basic Rate Interface Media Bay Module (BRIM S/T)
• Four modular RJ-45 jacks
•Supports four S/T interfaces (8 B-channels)
• T-interface to connect to an NT1 device or an S-interface to connect
ISDN terminals
•Supports ETSI and National ISDN BRI
• Two LEDs: Power, Status
• Utilizes 1/3 DS-30
Global Analog Trunk Module (GATM 4)
• One Amphenol (male) connector for analog North American, UK and
Australia Standard
• Four loop start CLASS/CMS lines plus one auxiliary port for V.90
modem, fax, analog telephone connection or Power Fail Transfer
• Two LEDs: Power, Status
• Utilizes 1/4 DS-30
Global Analog Trunk Module (GATM 8)
• One Amphenol (male) connector for analog North American, UK and
Australia Standard
• Eight loop start CLASS/CMS lines plus one auxiliary port for V.90
modem, fax, analog telephone connection or Power Fail Transfer
• Two LEDs: Power, Status
• Utilizes 1/2 DS-30
Fiber Expansion Media Bay Module (FEM)
• Six fiber ports
•Connects up to six Norstar* fiber-based trunk or station modules
• Two LEDs: Power, Status
• Utilizes 1 DS-30 for each Norstar fiber trunk or station module
connected (up to 6)
Global 4X16 Module (4 Caller ID trunks + 16 Station sets, G4x16)
• One Amphenol (male) connector (25 pair) to support four loop start
CLASS/CMS lines plus one auxiliary port for V.90 modem, fax, analog
telephone connection, or Power Fail Transfer
• One Amphenol (male) connector (25 pair) to support 16 digital phone
ports
• Individual Station interfaces are current limited to 80mA
• Two LEDs: Power, Status
• Utilizes 1 1/4 DS-30s
Global 8X16 Module (8 Caller ID trunks + 16 Station Sets, G8X16)
• One Amphenol (male) connector (25 pair) to support eight loop start
CLASS/CMS lines plus one auxiliary port for V.90 modem, fax, analog
telephone connection or Power Fair Transfer
• One Amphenol (male) connector (25 pair) to support 16 digital phone
ports
• Individual Station interfaces are current limited to 80mA
• Two LEDs: Power, Status
• Utilizes 1 1/2 DS-30s
ADID Module (Analog Direct Inward Dial 4-Port or 8-Port,
ADID4 and ADID8)
• One Amphenol (male) connector (25 pair) to support four or eight
ADID lines
• Two LEDs: Power, Status
• Utilizes 1/4 DS-30 (ADID4) or 1/2 DS-30 (ADID8)
•Currently North America DID standard
Data networking components of the Nortel BCM 400 and Data networking components of the Nortel BCM 200
Embedded v.92 Modem
• For Dial Backup or Remote Admin
•V.92 56 kbps ITU standard
•V.34 33.6 kbps ITU standard
•RJ-11 connector
•V.42/MNP 2-4 error control
•V.42/MNP 5 data compression
•Capable of receiving data at 56 kbps and sending data at 31.2 kbps
10/100 Ethernet LAN interface
• 10/100BASE-T Ethernet ports (on board the mainboard)
•Supports IEEE 802.3 Ethernet frame format
•Uses Carrier Sense Multiple Access with Collision Detection
(CSMA/CD)
• 100BASE-TX with RJ-45 connector
• 10/100 Auto-sensing
• Full-duplex support
•PPPoE (enabled using keycode)
WAN interface
Two port PCI card (field installable)
•Each port can be independently configured to Frame Relay or PPP
•STAC compression support
• One serial sync port (V.35) and one T1 port with integrated CSU and
DSU connectivity — N.A. only
• Two serial ports (V.35)
• Two serial ports (V.35 and X.21) – EMEA only
• Frame Relay or PPP Fragmentation
•RTP Header Compression
ISDN via MBMs
• Up to 16 ISDN B-channels
• (PRI or BRI) (optional)
• Dial on demand, Persistent or WAN Backup
•MLPPP
Expansion Cabinet (BCM400 and BCM1000 only)
Connections
• Six Media Bay Module slots
• An 8-pin modular DS256 connector for the interface to the Business
Communications Manager base unit (5 meter cable)
Standard Expansion Cabinet
Depth 18.3 in.; 46.5 cm
Width 17.5 in.; 44.5 cm
Height 5.4 in.; 13.6 cm
Expansion Cabinet with no Media Bay Modules 24.75 lb.; 11.25 kg
Expansion Cabinet with six Media Bay Modules 39 lb.; 17.75 kg
Redundant Expansion Cabinet (redundant power supply and fans)
Depth 20 in.; 53.8 cm
Width 17.6 in.; 44.6 cm
Height 5.4 in.; 13.6 cm
Expansion Cabinet with no Media Bay Modules 31.9 lb.; 14.5 kg
Expansion Cabinet with 6 Media Bay Modules 46.2 lb.; 21 kg
Power requirements of the Nortel BCM 400 and Power requirements of the Nortel BCM 200
Standard Power Supply Redundant Power Supply
Auto-sensing Auto-sensing
300 Watts 350 Watts
90/264 VAC 90/264 VAC
6.0 A/3.0 A 7.0 A/3.5 A
60/50 Hz 60/50 Hz
Environmental ranges of the Nortel BCM 400 and Environmental ranges of the Nortel BCM 200
Operating temperature 32º to 104ºF; 0º to 40ºC
Operating humidity 10% to 90% relative humidity,
non-condensing
Storage temperature -67º to 158ºF; -55º to 70ºC
Storage humidity Up to 95% relative humidity
Mounting options
Rack-mount (standard 19-inch rack); Stand-alone (feet included);
Wall-mount (optional wall-mount bracket available separately)
Telephones and Adapters of the Nortel BCM 400
Station Sets of the Nortel BCM 400
Business Series of the Nortel BCM 400
North Dimensions Loop Length With SAPS
America (Inches) (26G) sets
T7100 8.1D x 7Wx3.5H 1,000 ft. 2,600 ft.
T7208 8.1D x 7.7Wx3.5H 1,000 ft 2,600 ft.
T7316E 8.1D x 10.3Wx3.5H 1,000 ft. 2,600 ft.
T24 KIM 7.7D x 3.6Wx3.4H Connects to T7316E
NACU 12.5 x 12Wx2H 1,000 ft. 2,600 ft.
IP phones of the Nortel BCM 400 and IP telephone of the Nortel BCM 200
Nortel BCM IP Phones
• Nortel IP Phone 1120E
• Nortel IP Phone 1140E
• Nortel IP Phone 2007
• Nortel IP Phone 2004
• Nortel IP Phone 2002
• Nortel IP Phone 2001
• Nortel IP Phone 2033
• Nortel IP Softphone 2050 (PC or Laptop)
T24 Kim—requires T7316E
T24 EKIM (Enhanced KIM — used as CAP) — max. 12 positions per
system; max 4 EKIMs per position
T24 OKIM (Ordinary KIM — used for answer/DSS/BLF) — unlimited per
system; max 4 OKIMs without power supply per position; max 9
OKIMs with power supply per position
WLAN of the Nortel BCM
• WLAN Handset 2210
• WLAN Handset 2211
• WLAN Handset 2212
• WLAN IP Telephony Manager 2245
• WLAN Applications Gateway 2246
• Nortel Mobile Voice Client 2050
Digital Mobility
• Digital Mobility Controller
• Digital Mobility Basestation
• Digital Mobility Repeater
• Digital Mobility Handsets 7420, 743x, 744x, 413x, 414x
Mobility — Cordless
T7406: 3 handsets per basestation, 2 basestations per system
Accessories of the Nortel BCM
Nortel BCM 400 and Nortel BCM 200
Doorphone
Norstar Audio Conferencing Unit (NACU)
Station Auxiliary Power Supply (SAPS)
ATA-2 Analog Terminal
BCM400 Installation Guide
BCM400 Maintenance Guide